In a special feature

 Quantity of generation of the renewable energy increases, but the quantity of generation is unstable. Therefore large-scale accumulation of electricity facilities are considered for stabilization when I connect renewable energy to an electric power system.
On the other hand, as for the electricity contract, it is thought that the electricity storage technology becomes more and more important by night by the spread, promotion of electricity rate type demandodesuponsu, contract electricity reduction (peak cut), "the promotion of the equalization of the electric demand" of the energy saving method when I think at a building level although it is abolished. Not the stability of the electric power system, I have you comment on the facilities which you can adopt as building facilities this time.

特集目次
特集に当たって
  本誌編集専門委員 村田 美久、今村 直大、酒井 重嘉
1.高調波とは
 1-1 スイッチング波形のフーリエ級数表現
  本誌編集専門委員 村田 美久
 1-2 直列リアクトル6%と13%の違い
  ㈱指月電機製作所 片岡 義則
 1-3 高調波の分流モデル 本誌編集専門委員 村田 美久
 1-4 高調波の最近の傾向(障害発生事例)
  日新電機㈱ 長崎 則久
2.高調波流出電流計算書(その1)の仕組み
  本誌編集専門委員 村田 美久
3.高調波流出電流計算書(その2)の仕組み
 3-1 高調波流出電流の詳細計算と対策要判定時の追加対策
  ㈱指月電機製作所 片岡 義則、田丸 裕也、岡田 拓也
 3-2 対策要判定の場合の追加対策2
  住友電設㈱ 吉田 裕一
 3-3 対策要判定の場合の追加対策3
  住友電設㈱ 吉田 裕一
4.構内進相コンデンサ設備への高調波流入量の検討
 4-1 進相コンデンサ設備の高調波耐量規格
  資料提供:ニチコン㈱
 4-2 進相コンデンサ設備への高調波流入量の計算
  住友電設㈱ 吉田 裕一
 4-3 耐量を超えた場合の進相コンデンサ設備の選定
  ㈱関電工 坂本 英雄
5.高調波監視機器および測定器
  ㈱きんでん 石松 康治
 